6-20L LPG/NG Tankless Gas Water Heater with Water Flow Sensor
6-20l lpg ng gas water heater with flow sensor supplier supports gas water heater replacement, maintenance and OEM service-stock planning. Confirm the original part, dimensions, connectors and installation conditions before ordering. 6-20L LPG/NG tankless gas water heater with water flow sensor for distributors and OEM programs that need automatic demand detection across a range of household applications. Confirm flow-start requirements, gas type, water pressure, and control interface before sampling.
Best for: buyers who need a model matched to real low-flow shower or tap conditions rather than a generic capacity-only quotation.
Place of Origin: China
Minimum Order Quantity: 50 pcs
Payment Terms: L/C, T/T, Western Union
Supply Ability: 30000 pcs per month
Port: Zhongshan, Guangzhou, Shenzhen
Delivery time: By T/T, within 30 days after receiving 30% deposit
Flow-sensor configuration for 6-20L tankless gas water heaters
This page is for buyers evaluating a tankless LPG or natural-gas water heater with a water-flow-sensor configuration. The flow-sensor selection must match the intended heater capacity, activation conditions, valve arrangement and control system. Confirm the exact sensor configuration before sampling or bulk production.
What to confirm for a flow-sensor configuration
- Required hot-water supply: 6L, 7L, 8L, 10L, 12L, 14L, 16L or 20L.
- Destination gas type: LPG or natural gas.
- Specified operating water-pressure range: 0.02-0.8MPa.
- Required activation-flow behaviour for the intended installation.
- Sensor connector, control-board and valve compatibility for the selected configuration.
- Whether a replacement-sensor and spare-parts plan is required for after-sales service.
Why water flow must be evaluated with the full installation
Water-flow behaviour is affected by more than one component. Inlet filters, pipe size, valves, inlet pressure, water quality and the selected heater configuration can all affect operation. For this reason, a sample should be checked using the target gas type and the intended installation conditions before confirming a production configuration.
Series capacity reference
| Hot-water supply | Rated heat load | Product size (mm) |
|---|---|---|
| 6L | 12KW | 440 × 300 × 120 |
| 7L | 14KW | 500 × 300 × 155 |
| 8L | 16KW | 520 × 320 × 155 |
| 10L | 20KW | 590 × 340 × 180 |
| 12L | 24KW | 620 × 340 × 180 |
| 14L | 28KW | 650 × 395 × 188 |
| 16L | 32KW | 650 × 395 × 188 |
| 20L | 40KW | 700 × 440 × 188 |
Flow-sensor RFQ checklist
Provide the target capacity, gas type, operating water-pressure conditions, intended installation, connector/control-system requirements, expected volume and sample-test requirement. This information allows the factory to review the suitable configuration rather than treating “flow sensor” as a generic product claim.
Flow-sensor product FAQ
Is a flow sensor by itself enough to solve low-flow complaints? No. Installation water pressure, filters, pipework, valves and the full heater configuration also need review.
Can a replacement-sensor strategy be included in an OEM order? Confirm the selected configuration and required spare-parts scope when requesting a quotation.
Gas Water Heater Product Details
Capacity: 6L-20L
Fuel Type: LP Gas & Natural Gas
Water Pressure: 0.02-0.8MPa
Thermal Efficiency: >=85%
Heat Exchanger Material: Copper
Ignition Type: Auto Ignition
Power Source: Battery, Gas
Exhaust Way: Flue Exhaust

Features
1. Flue exhaust instant gas water heater;
2. Low water pressure start-up function, big flow rate;
3. White or any color powder coating, SS, glass panel;
4. Fully water-controlled automatic impulse ignition;
5. Flame-out protection;
6. Anti-dry combustion protection;
7. Over-pressure and water drainage anti-freezing protection (optional);
8. Overheating protection;
9. Advanced combustion system with the Winter/summer switch to save energy (optional);
10. 20 minutes auto-off (optional);
11. Colorful LCD temperature display to know water temperature and working status (optional).
Product specification

Product loading quantity
Series | Hot Water Supply L/Min △t 25°C | Rated Heat Load | Product Size(mm) | Packing Size(mm) | Loading Quantity 20GP/40HQ(PCS) |
| 1 | 6L | 12KW | 440*300*120 | 520*335*180 | 900/2150 |
| 2 | 7L | 14KW | 500*300*155 | 610*355*190 | 680/1640 |
| 3 | 8L | 16KW | 520*320*155 | 610*370*205 | 610/1460 |
| 4 | 10L | 20KW | 590*340*180 | 670*405*230 | 465/1070 |
| 5 | 12L | 24KW | 620*340*180 | 710*405*230 | 430/1010 |
| 6 | 14L | 28KW | 650*395*188 | 720*460*240 | 350/840 |
| 7 | 16L | 32KW | 650*395*188 | 720*460*240 | 350/840 |
| 8 | 20L | 40KW | 700*440*188 | 800*490*240 | 290/710 |
Customised service
Heat Exchanger

Valve
Zero-water-pressure valve or Normal water-pressure valve.

Knob and Display Options

Gas Water Heater Factory FAQ
Yes. We are a professional gas water heater factory founded in 1997, with experience in OEM and ODM production.
Our MOQ is 50 pieces per model.
Sample preparation usually takes 10 to 20 days, depending on the model and customization requirements.
Yes. OEM orders are welcome. We can support customized branding, packaging, and product specifications.
The standard delivery time is about 30 days after the order is confirmed and the deposit is received.
Our payment term is T/T: 30% deposit in advance and 70% balance before shipment
WhatsApp: +86 158 7604 6823
Water-flow sensor selection for tankless gas heaters
A flow sensor can affect when the heater detects demand and begins its heating sequence. Low-flow complaints are not always caused by the sensor alone; filters, scale, inlet pressure, valves, pipe size, and gas supply can also affect the result.
Useful RFQ information
- Minimum activation flow and normal operating flow
- Water pressure range and water-quality conditions
- LPG or natural gas and target capacity
- Sensor connector, control board, and replacement strategy
- Expected annual volume and sample test plan
We can review the application and recommend a compatible configuration for OEM or distributor sourcing. Final commissioning should be completed by a qualified local technician.
Ask about a flow-sensor model: info@kechangwaterheater.com | WhatsApp +86 158 7604 6823
Gas water heater with flow sensor: selection points
This 6-20L LPG/NG tankless gas water heater includes a flow-sensor selection angle. Confirm activation flow, sensor plug, water-pressure range, fuel configuration and target heater model so the start signal matches the intended installation.
Before ordering
- Required minimum flow and number of outlets
- Sensor connector, body and control-system details
- Destination fuel type, capacity and packaging needs
Compare other flow-related models and send your application details for review.
Starting at US$26. Final pricing depends on the model, specifications, MOQ, and order quantity. Request a quote.